ºÚÁϳԹÏ

EasySep? Human Monocyte Enrichment Kit

Immunomagnetic negative isolation of untouched human monocytes

New look, same high quality and support! You may notice that your instrument or reagent packaging looks slightly different from images displayed on the website, or from previous orders. We are updating our look but rest assured, the products themselves and how you should use them have not changed. Learn more

EasySep? Human Monocyte Enrichment Kit

Immunomagnetic negative isolation of untouched human monocytes

Catalog #
(Select a product)
Immunomagnetic negative isolation of untouched human monocytes
Request Pricing

Product Advantages


  • Fast, easy-to-use and column-free

  • Up to 95% purity

  • Untouched, viable cells

What's Included

  • EasySep? Human Monocyte Enrichment Kit (Catalog #19059)
    • EasySep? Human Monocyte Enrichment Cocktail, 1 mL
    • EasySep? Magnetic Particles, 1 mL
  • RoboSep? Human Monocyte Enrichment Kit with Filter Tips (Catalog #19059RF)
    • EasySep? Human Monocyte Enrichment Cocktail, 1 mL
    • EasySep? Magnetic Particles, 1 mL
    • RoboSep? Buffer (Catalog #20104)
    • RoboSep? Filter Tips (Catalog #20125)

Overview

Easily and efficiently isolate highly purified human (CD14+CD16-) monocytes from fresh or previously frozen human peripheral blood mononuclear cells (PBMCs) or lysed leukapheresis samples by immunomagnetic negative selection, with the EasySep? Human Monocyte Enrichment Kit. Widely used in published research for more than 20 years, EasySep? combines the specificity of monoclonal antibodies with the simplicity of a column-free magnetic system.

In this EasySep? negative selection procedure, unwanted cells are labeled with antibody complexes and magnetic particles. The following unwanted cells are targeted for removal: granulocytes, T cells, B cells, dendritic cells, NK cells, and erythroid cells. The magnetically labeled cells are then separated from the untouched desired human monocytes by using an EasySep? magnet and simply pouring or pipetting the desired cells into a new tube. Following magnetic cell isolation, the desired monocytes are ready for downstream applications such as flow cytometry, culture, or DNA/RNA extraction.

For applications in which CD16+ cells are not removed, we recommend the EasySep? Human Monocyte Enrichment Kit without CD16 Depletion (Catalog #19058).

For even faster cell isolations, we recommend the EasySep? Human Monocyte Isolation Kit (Catalog #19359), which isolates cells in just 12.5 minutes.

Learn more about how immunomagnetic works or how to fully automate immunomagnetic cell isolation with RoboSep?. Alternatively, choose ready-to-use, ethically sourced, primary Human Peripheral Blood Monocytes, Frozen isolated with EasySep? Human Monocyte Enrichment Kit. Explore additional products optimized for your workflow, including culture media, supplements, antibodies, and more.
Magnet Compatibility
? EasySep? Magnet (Catalog #18000)
? ¡°The Big Easy¡± EasySep? Magnet (Catalog #18001)
? Easy 50 EasySep? Magnet (Catalog #18002)
? EasyPlate? EasySep? Magnet (Catalog 18102)
? RoboSep?-S (Catalog #21000)
Subtype
Cell Isolation Kits
Cell Type
Monocytes
Species
Human
Sample Source
PBMC
Selection Method
Negative
Application
Cell Isolation
Brand
EasySep, RoboSep
Area of Interest
Immunology

Data Figures

FACS Profile Results Using EasySep™ Human Monocyte Enrichment Kit

Figure 1. FACS Profile Results Using EasySep™ Human Monocyte Enrichment Kit

Starting with previously frozen peripheral blood mononuclear cells, the monocyte content of the enriched fraction typically ranges from 83% - 95%.

Protocols and Documentation

Find supporting information and directions for use in the Product Information Sheet or explore additional protocols below.

Document Type
Product Name
Catalog #
Lot #
Language
Document Type
Product Name
Catalog #
19059RF
Lot #
All
Language
English
Document Type
Product Name
Catalog #
19059
Lot #
All
Language
English
Document Type
Product Name
Catalog #
19059RF
Lot #
All
Language
English
Document Type
Product Name
Catalog #
19059RF
Lot #
All
Language
English
Document Type
Product Name
Catalog #
19059RF
Lot #
All
Language
English
Document Type
Product Name
Catalog #
19059
Lot #
All
Language
English
Document Type
Product Name
Catalog #
19059
Lot #
All
Language
English

Applications

This product is designed for use in the following research area(s) as part of the highlighted workflow stage(s). Explore these workflows to learn more about the other products we offer to support each research area.

Resources and Publications

Frequently Asked Questions

Can EasySep™ be used for either positive or negative selection?

Yes. The EasySep™ kits use either a negative selection approach by targeting and removing unwanted cells or a positive selection approach targeting desired cells. Depletion kits are also available for the removal of cells with a specific undesired marker (e.g. GlyA).

How does the separation work?

Magnetic particles are crosslinked to cells using Tetrameric Antibody Complexes (TAC). When placed in the EasySep™ Magnet, labeled cells migrate to the wall of the tube. The unlabeled cells are then poured off into a separate fraction.

Which columns do I use?

The EasySep™ procedure is column-free. That's right - no columns!

How can I analyze the purity of my enriched sample?

The Product Information Sheet provided with each EasySep™ kit contains detailed staining information.

Can EasySep™ separations be automated?

Yes. RoboSep™, the fully automated cell separator, automates all EasySep™ labeling and cell separation steps.

Can EasySep™ be used to isolate rare cells?

Yes. We recommend a cell concentration of 2x108 cells/mL and a minimum working volume of 100 µL. Samples containing 2x107 cells or fewer should be suspended in 100 µL of buffer.

Are the EasySep™ magnetic particles FACS-compatible?

Yes, the EasySep™ particles are flow cytometry-compatible, as they are very uniform in size and about 5000X smaller than other commercially available magnetic beads used with column-free systems.

Can the EasySep™ magnetic particles be removed after enrichment?

No, but due to the small size of these particles, they will not interfere with downstream applications.

Can I alter the separation time in the magnet?

Yes; however, this may impact the kit's performance. The provided EasySep™ protocols have already been optimized to balance purity, recovery and time spent on the isolation.

For positive selection, can I perform more than 3 separations to increase purity?

Yes, the purity of targeted cells will increase with additional rounds of separations; however, cell recovery will decrease.

How does the binding of the EasySep™ magnetic particle affect the cells? is the function of positively selected cells altered by the bound particles?

Hundreds of publications have used cells selected with EasySep™ positive selection kits for functional studies. Our in-house experiments also confirm that selected cells are not functionally altered by the EasySep™ magnetic particles.

If particle binding is a key concern, we offer two options for negative selection. The EasySep™ negative selection kits can isolate untouched cells with comparable purities, while RosetteSep™ can isolate untouched cells directly from whole blood without using particles or magnets.

Publications (27)

Activation of human ?? T cells and NK cells by Staphylococcal enterotoxins requires both monocytes and conventional T cells. M. Mata Forsberg et al. Journal of leukocyte biology 2022 mar

Abstract

Staphylococcal enterotoxins (SE) pose a great threat to human health due to their ability to bypass antigen presentation and activate large amounts of conventional T cells resulting in a cytokine storm potentially leading to toxic shock syndrome. Unconventional T- and NK cells are also activated by SE but the mechanisms remain poorly understood. In this study, the authors aimed to explore the underlying mechanism behind SE-mediated activation of MAIT-, ?? T-, and NK cells in vitro. CBMC or PBMC were stimulated with the toxins SEA, SEH, and TSST-1, and cytokine and cytotoxic responses were analyzed with ELISA and flow cytometry. All toxins induced a broad range of cytokines, perforin and granzyme B, although SEH was not as potent as SEA and TSST-1. SE-induced IFN-$\gamma$ expression in MAIT-, ?? T-, and NK cells was clearly reduced by neutralization of IL-12, while cytotoxic compounds were not affected at all. Kinetic assays showed that unconventional T cell and NK cell-responses are secondary to the response in conventional T cells. Furthermore, co-cultures of isolated cell populations revealed that the ability of SEA to activate ?? T- and NK cells was fully dependent on the presence of both monocytes and $\alpha$$\beta$ T cells. Lastly, it was found that SE provoked a reduced and delayed cytokine response in infants, particularly within the unconventional T and NK cell populations. This study provides novel insights regarding the activation of unconventional T- and NK cells by SE, which contribute to understanding the vulnerability of young children towards Staphylococcus aureus infections.
IL-10 Dysregulation Underlies Chemokine Insufficiency, Delayed Macrophage Response, and Impaired Healing in Diabetic Wounds. R. Roy et al. The Journal of investigative dermatology 2022 mar

Abstract

Persistent inflammation is a major contributor to healing impairment in diabetic chronic wounds. Paradoxically, diabetic wound environment during the acute phase of healing is completely different because it exhibits a reduced macrophage response owing to inadequate expression of CCL2 proinflammatory cytokine. What causes a reduction in CCL2 expression in diabetic wounds early after injury remains unknown. In this study, we report that in contrast to prolonged exposure to high glucose, which makes monocytes proinflammatory, short-term exposure to high glucose causes a rapid monocyte reprogramming, manifested by increased expression and secretion of IL-10, which in an autocrine/paracrine fashion reduces glucose uptake and transforms monocytes into an anti-inflammatory phenotype by dampening signaling through toll-like receptors. We show that IL-10 expression is significantly increased in diabetic wounds during the acute phase of healing, causing significant reductions in toll-like receptor signaling and proinflammatory cytokine production, delaying macrophage and leukocyte responses, and underlying healing impairment in diabetic wounds. Importantly, blocking IL-10 signaling during the acute phase of healing improves toll-like receptor signaling, increases proinflammatory cytokine production, enhances macrophage and leukocyte responses, and stimulates healing in diabetic wounds. We posit that anti-IL-10 strategies have therapeutic potential if added topically after surgical debridement, which resets chronic wounds into acute fresh wounds.
Impaired immunomodulatory effects of seminal plasma may play a role in unexplained recurrent pregnancy loss: Results of an in vitro study. N. A. du Foss\'e et al. Journal of reproductive immunology 2022 jun

Abstract

BACKGROUND Seminal plasma contains signaling molecules capable of modulating the maternal immune environment to support implantation and pregnancy. Prior studies indicated that seminal plasma induces changes in gene transcription of maternal immune cells. Reduced immune suppressive capacity may lead to pregnancy loss. The aim of this study was to investigate the immunomodulating effects of seminal plasma on T cells and monocytes in the context of recurrent pregnancy loss (RPL). METHODS Female T cells and monocytes were incubated with seminal plasma of 20 males in unexplained RPL couples (RPL males) and of 11 males whose partners had ongoing pregnancies (control males). The effect of seminal plasma on messenger RNA (mRNA) expression of immune cells was measured. Levels of mRNA expression were related to key signaling molecules present in the seminal plasma. Agglomerative hierarchical cluster analysis was performed on seminal plasma expression profiles and on mRNA expression profiles. RESULTS Expression of CD25 and anti-inflammatory IL-10 by female T cells was significantly lower after stimulation with seminal plasma of RPL males compared to control males. Female monocytes treated with seminal plasma of RPL males showed an immune activation signature of relatively elevated HLA-DR expression. Expression of these T cell and monocyte components was particularly correlated with the amounts of TGF-$\beta$ and VEGF in the seminal plasma. CONCLUSION Our findings indicate that seminal plasma has immunomodulating properties on female immune cells compatible with the induction of a more regulatory phenotype, which may be impaired in cases of unexplained RPL.
New look, same high quality and support! You may notice that your instrument or reagent packaging looks slightly different from images displayed on the website, or from previous orders. We are updating our look but rest assured, the products themselves and how you should use them have not changed. Learn more